A303 - Enlarged Building Section

A303 - Enlarged Building Section

View Type
Sheet
View Template
Drawing Scale
3/8" = 1'-0"
Titleblock: see  A - Titleblock⁠ 

Drawing Sample:


It appears you do not have a PDF plugin for this browser.

Drawing Checklist:

View Title cw. View Name & Number
Detail Group
Framing Detailing
FRR Linework
Insulation (Refer to Note #2)
Section Detail Callouts / References
Datum Dims and Extents for Levels & Grids
Assembly Tags
Window Tags
Door Tags
Tread Numbers on Stairs (Refer to Note #1)
Dimensions;
Clear Heights, Should be a Continuous String (Refer to Note #2)
Ceiling Heights
Bulkhead Offsets / Plenum Depths
Floor Assembly Total Thickness
Cantilever Lengths & Offsets
Window Openings, Sills & Head Heights
Door Openings, Sill Offset from Floor
Clear Stairwell Height(s)


Note #1

On Sites where the stairs vary by unit count, use a note referring to Site Plan or Precast drawings instead of tread numbers and Spot Elevations
  • Spot Elevations
  • Top of Stairs
  • Bottom of Stairs
  • Landings
  • Tread Numbers on Stairs


Note #2 – Exterior stairs and decks

For enlarged sections of exterior stairs, decks and landings, these checklist items are N/A: clear heights (ceiling heights, bulkhead or plenum depths), floor assembly thickness, insulation and FRR linework. Check these instead:
  • Tread numbers, or riser and tread dimensions
  • Guard and handrail heights
  • Spot elevations at the top and bottom of the stairs and at landings
  • Deck or stair assembly tag
  • Relationship to grade and footings


View Naming

  • Callout from another drawing (e.g. called from a Building Section or Unit Sheet): Building Section - Enlarged Callout ###
  • Independent view: Enlarged Building Section ###
  • Descriptive names are not required. Each view still requires a view title with number and scale.