- Concrete needs to be modelled 100% separately. Walls that are part concrete should be modelled in two parts; i.e. a basement wall that is framed on the inside would be modelled as one concrete wall that is placed adjacent another wall that contains the studs, air space and GWB. Best practice would be to use a common location line between these walls so that changes in the assembly do not cause major rework.
Start a new file based on the company template.
Save the file locally on your machine.
Navigate to > > .
Rename the standard worksets to match your project needs. (Workset1 > "Architecture")
Create new worksets as required ("Link-Site").
Save & Synchronize the model.
Set the model point origin as the grid origin. (In the template, this is Grid 01-A.)
Create grids for the building using the tool or create new ones as needed.
Space the grids correctly, ensuring they match the design.
Ensure the grids are in the correct Workset named "Shared Levels and Grids."
Synchronize the model.
Open an Elevation view and create new levels using the tool.
Ensure the levels are spaced correctly.
Confirm that the levels are placed in the "Shared Levels and Grids" Workset.
Synchronize the model.
Go to Main Floor Level in your project. P.S. You can do it in 3D View if WP is matching your main level.
Navigate to > > .
- Find and select the appropriate model group.
- Ensure you select .
- Do select or .
Place the model group on the grid.
Repeat the process for all required model groups.
Create a around your model groups, ensuring they are centered within the box.
Align the scope box in 3D space, leaving space for the foundation.
Apply the to all floor plan views for consistency.
Check is "Shared Levels and Grids"
For Levels and Grids apply limits to the .
Insert ➝ Link RVT ➝ Choose file
Positioning: Auto - Internal Origin to Internal Origin
Move/Rotate/Align the whole linked Site element to the Building assembly.
Check Workset for Site element Link-Site.
LMC on Site ➝ Property ➝ Shared Site ➝ Choose option
Quick Tip: If Selection is grey (not active) ➝ go and "Reset Shared Coordinates"
Synchronize the model.
Go to Working file (...Site.rvt)
Insert ➝ Link RVT ➝ Choose file
Positioning: Auto - By Shared Coordinate
Similar to prev. steps select Shared Site for building (if not applied)