LP Prototype Specifications

LP Prototype Specifications

4. LP Prototype Specifications

Construction Assemblies

Walls

  • EC04 Exterior Precast Wall Panels 11"
  • EW6.b 2x6 Wood Envelope Wall
  • EW8.b 2x8 Wood Envelope Wall
  • EW4.w 2x4 Wood Exterior Wing Wall
  • PW4.a 2x4 Wood Partition
  • PW6.a 2x6 Wood Partition
  • PW01 2x6 Wood Partition Loadbearing
  • PW.a 2x4 Build-Out Wall
  • PW.b 2x6 Build-Out Wall
Type Mark
Type
Fire Rating
Assembly Listing
Code Reference
EC04
Exterior Precast Wall Panels 11"
2 FSR
Exterior Face of Wall(Varies) Exterior Formliner Finish - Refer to Elevations11" [280mm] Precast 'Sandwich' Wall Panel- 3.5" [89mm] Precast Concrete, Reinforced as per Structural Design- 4" [102mm] Rigid Insulation Core R20- 3.5" [89mm] Precast Concrete, Reinforced as per Structural DesignInterior Face of Wall
NBC AE 2023: Appendix D 2.1
EW6.b
2x6 Wood Envelope Wall
Not-Rated
Exterior Face of Wall(Varies) Exterior Finish - Refer to Elevations(Varies) Cladding Rainscreen - As Specified[Membrane Layer] Weather Resistive Barrier, Tyvek CommercialWrap of Approved Equivalent1/2" [13mm] Plywood Sheathing5 1/2" [140mm] 2x6 Nominal Wood Framing, Spacing as Per Structural Design5 1/2" [140mm] Thermal Batt Insulation in Stud Cavity[Membrane Layer] 6 Mil. Poly Vapour Retarder1/2" [13mm] GWBPrimed, Taped & Muded SeamsFinished, See Interior ElevationsInterior Face of Wall
EW8.a
2x8 Wood Envelope Wall
Not-Rated
Exterior Face of Wall(Varies) Exterior Finish - Refer to Elevations(Varies) Cladding Rainscreen - As Specified[Membrane Layer] Weather Resistive Barrier, Tyvek CommercialWrap of Approved Equivalent1/2" [13mm] Plywood Sheathing7 1/4" [184mm] 2x8 Nominal Wood Framing, Spacing as Per Structural Design7 1/4" [184mm] Thermal Batt Insulation in Stud Cavity[Membrane Layer] 6 Mil. Poly Vapour Retarder1/2" [13mm] GWBPrimed, Taped & Muded SeamsFinished, See Interior ElevationsInterior Face of Wall
EW4.w
2x4 Wood Exterior Wing Wall
Not-Rated
Exterior Face of Wall(Varies) Exterior Finish - Refer to Elevations(Varies) Cladding Rainscreen - As Specified[Membrane Layer] Weather Resistive Barrier, Tyvek CommercialWrap of Approved Equivalent3 1/2" [89mm] 2x4 Nominal Wood Framing, Spacing as Per Structural DesignBack Face of WallNote: Refer to Plans and Details for Size and Layout of Wing Walls / Arches / Columns
PW4.a
2x4 Wood Partition
Not-Rated
Interior Face of WallFinished, See Interior ElevationsPrimed, Taped & Muded Seams1/2" [13mm] GWB3 1/2" [89mm] 2x4 Wood Studs, Spacing as Per Structural Design3 1/2" [89mm] Sound Attenuating Batt Insulation in Stud Cavity, Fiberglass or Equivalent1/2" [13mm] GWBPrimed, Taped & Muded SeamsFinished, See Interior ElevationsInterior Face of WallNote: Soundproof Insulation to be Added Where Indicated on Plans & Sections
PW6.a
2x6 Wood Partition
Not-Rated
Interior Face of WallFinished, See Interior ElevationsPrimed, Taped & Muded Seams1/2" [13mm] GWB5 1/2" [140mm] 2x6 Wood Studs, Spacing as Per Structural Design5 1/2" [140mm] Sound Attenuating Batt Insulation in Stud Cavity, Fiberglass or Equivalent1/2" [13mm] GWBPrimed, Taped & Muded SeamsFinished, See Interior ElevationsInterior Face of WallNote: Additional Soundproof Insulation to be Added Where Indicated on Plans & Sections
PW01
2x6 Wood Partition Loadbearing
1 FSR
Interior Face of WallFinished, See Interior ElevationsPrimed, Taped & Muded Seams5/8" [16mm] Type-X GWB5 1/2" [140mm] 2x6 Wood Studs, Spacing as Per Structural Design5 1/2" [140mm] Sound Attenuating Batt Insulation in Stud Cavity, Fiberglass or Equivalent5/8" [16mm] Type-X GWBPrimed, Taped & Muded SeamsFinished, See Interior ElevationsInterior Face of WallNote: Additional Soundproof Insulation to be Added Where Indicated on Plans & Sections
ULC W301- Cavity Insulation, STC Rating = 32
PW.a
2x4 Build-Out Wall
Not-Rated
Face of Other Assembly3 1/2" [89mm] 2x4 Wood Studs, Spacing as Per Structural Design1/2" [13mm] GWBPrimed, Taped & Muded SeamsFinished, See Interior ElevationsInterior Face of Wall
PW.b
2x6 Build-Out Wall
Not-Rated
Face of Other Assembly5 1/2" [140mm] 2x6 Wood Studs, Spacing as Per Structural Design1/2" [13mm] GWBPrimed, Taped & Muded SeamsFinished, See Interior ElevationsInterior Face of Wall

Floors

  • F31 5" Exterior CIP Concrete Slab-on-Grade (cw Ball Management System)
  • F32 5" Exterior CIP Concrete Slab-on-Grade
  • F33 5" Interior CIP Concrete Slab-on-Grade
  • F34 10" Hollowcore Slabs cw. 5" Topping (cw Ball Management System)
  • F35 10" Hollowcore Slabs cw. 2" Topping
Type Mark
Type
Fire Rating
Assembly Listing
Code Reference
F31
5" Exterior CIP Concrete Slab-on-Grade (cw Ball Management System)
Not-Rated
Top Face of Floor[Membrane Layer] Epoxy Membrane5" [127mm] Concrete Slab on Grade - Reinforced as Required; Refer to Structural15 Mil - Class A Polyethylene Vapour Retarder for Below Grade Applications6" [152mm] XPS Rigid Insulation for Below Grade ApplicationsMin. 6" [152mm] Crushed Granular Fill; Coarse, No FinesBottom Face of Floor - Established GradeNote: Ball Distribution Piping / Equipment Boxes to be Installed in Slab - Refer to DetailsNote: Refer to Sections and Details for Extents of Shallow Frost Protection
F32
5" Exterior CIP Concrete Slab-on-Grade
Not-Rated
Top Face of Floor[Membrane Layer] Epoxy Membrane5" [127mm] Concrete Slab on Grade - Reinforced as Required; Refer to Structural15 Mil - Class A Polyethylene Vapour Retarder for Below Grade Applications6" [152mm] XPS Rigid Insulation for Below Grade ApplicationsMin. 6" [152mm] Crushed Granular Fill; Coarse, No FinesBottom Face of Floor - Established GradeNote: Refer to Sections and Details for Extents of Shallow Frost Protection
F33
5" Interior CIP Concrete Slab-on-Grade
Not-Rated
Top Face of Floor[Membrane Layer] Epoxy Membrane5" [127mm] Concrete Slab on Grade - Reinforced as Required; Refer to Structural15 Mil - Class A Polyethylene Vapour Retarder for Below Grade ApplicationsMin. 6" [152mm] Crushed Granular Fill; Coarse, No FinesBottom Face of Floor - Established Grade
F34
Exterior 10" Hollowcore Slabs cw. 5" Topping (cw Ball Management System)
2 FSR
Top Face of Floor[Membrane Layer] Epoxy Membrane5" [127mm] Concrete Topping - Reinforced as Required; Refer to Structural10" [254mm] Precast Hollowcore Planks; Refer to StructuralSoffit / Ceiling Below; Refer to Building SectionsNote: Ball Distribution Piping / Equipment Boxes to be Installed in Topping - Refer to Details
NBC AE 2023: Appendix D 2.1
F35
Interior 10" Hollowcore Slabs cw. 2" Topping
2 FSR
Top Face of Floor[Varies] Finish Floor; Refer to Floor Finish Plans2" [51mm] Concrete Topping - Reinforced as Required; Refer to Structural10" [254mm] Precast Hollowcore Planks; Refer to StructuralSoffit / Ceiling Below; Refer to Building Sections
NBC AE 2023: Appendix D 2.1

Ceilings

  • C01 LGS Suspended Drywall Ceiling
  • C02 Applied Drywall Ceiling
Type Mark
Type
Fire Rating
Assembly Listing
Code Reference
C01
LGS Suspended Drywall Ceiling
Not-Rated
Underside of Supporting Structure[Varies] Ceiling Plenum for Mech. - Refer to Sections1 1/2" [38mm] Light Gauge Steel Ceiling Bar - Hung by Wire Cables to US of Structure1/2" [13mm] GWBPrimed, Taped & Muded SeamsFinished, See RCPExposed Face of Ceiling
C02
Applied Drywall Ceiling
Not-Rated
Underside of Supporting Structure[Varies] Ceiling Plenum for Mech. - Refer to Sections3/4" [19mm] Furring Strips Attached to US of Structure1/2" [13mm] GWBPrimed, Taped & Muded SeamsFinished, See RCPExposed Face of Ceiling

Roofs

  • R02.a Wood Truss Low Slope Cold Roof cw. Two-Ply Mod-Bit Roofing
  • R05.b Wood Truss Low Slope Canopy Roof cw. Two-Ply Mod-Bit Roofing
  • R08.b 16" OWJ Wood Framed Flat Warm Roof cw. Two-Ply Mod-Bit Roofing
Type Mark
Type
Fire Rating
Assembly Listing
Code Reference
R02.a
Wood Truss Low Slope Cold Roof cw. Two-Ply Mod-Bit Roofing
Not-Rated
Top of Roof AssemblySBS Two-Ply Modified-Bitumen Roofing Membrane7/16" [11mm] Roof Grade OSB Sheathing[Varies] Engineered Roof Truss Framing, Spacing as Per Structural DesignMin. 12" [305mm] Blown Fibreglass Insulation (R-45) in Truss Cavity; Atticat Pink or Equivalent[Membrane Layer] 6 Mil. Poly Vapour Retarder3/4" [19mm] Furring Strips @ 12" [305mm] O.C.1/2" [13mm] GWBPrimed, Taped & Muded SeamsFinished, See RCPUnderside of Roof Assembly &Exposed Face of CeilingNote: Truss heel is to be min. 18" [457mm] to accommodate insulation and baffle. Refer to Section Details.
R05.b
Wood Truss Low Slope Canopy Roof cw. Two-Ply Mod-Bit Roofing
Not-Rated
Top of Roof AssemblySBS Two-Ply Modified-Bitumen Roofing Membrane7/16" [11mm] Roof Grade OSB Sheathing[Varies] Engineered Roof Truss Framing, Spacing as Per Structural DesignMin. 12" [305mm] Blown Fibreglass Insulation (R-45) in Truss Cavity; Atticat Pink or Equivalent3/4" [19mm] Furring Strips @ 12" [305mm] O.C.1/2" [13mm] Aluminum V-Groove Soffit Panels - VentedFinished, See RCPUnderside of Roof Assembly &Exposed Face of Ceiling
R08.b
16" OWJ Wood Framed Flat Warm Roof cw. Two-Ply Mod-Bit Roofing
Not-Rated
Top Face of FloorTop of Roof AssemblySBS Two-Ply Modified-Bitumen Roofing MembraneRoof Protection / Cover Sheathing for InsulationAverage 7" [178mm] Rigid Roof Insulation: Slope to Drains/Scuppers[Membrane Layer] Air-Barrier / Vapour Control Layer3/4" [19mm] Roof Grade OSB Sheathing16" [406mm] Open Web Wood Joists, Spacing as Per Structural Design3/4" [19mm] Furring Strips @ 12" [305mm] O.C.1/2" [13mm] GWBPrimed, Taped & Muded SeamsFinished, See RCPExposed Face of Ceiling

Roof Soffits

  • Sa Built-Up Wood Soffit cw. Aluminum Lap Panel - Vented
Type Mark
Type
Fire Rating
Assembly Listing
Code Reference
Sa
Built-Up Wood Soffit cw. Aluminum Lap Panel - Vented
Not-Rated
Top of Roof Assembly[Varies] Supporting Structure - Backframe as Required for Soffit Heights: Refer to SectionsMin. 3/4" [19mm] Furring Strips @ 12" [305mm] O.C.1/2" [13mm] Aluminum V-Groove Soffit Panels - VentedUnderside of Assembly / Face of Exposed Soffit


Performance Requirements

Project Summary — Climate Zone Reference

NECB 2020 (energy) / NBC 2020 (structural, life-safety, glazing) — verify against locally adopted edition per province
City
Province
Approx. HDD18
NECB Zone
Adopted Energy Code
Adoption Notes
Local Overlay
Toronto
Ontario
~4,000 (approx.)
Zone 6
SB-10 (Div. 3.1) — verify current NECB vintage referenced
Ontario's SB-10 has historically referenced NECB 2017 w/ amendments; confirm whether NECB 2020 has been adopted for your permit date
Toronto Green Standard (may impose stricter performance than OBC/SB-10 minimum)
Calgary
Alberta
~5,000 (borderline 6/7A)
Zone 7A
Alberta Building Code — confirm NECB 2020 adoption date
Alberta adopted NBC/NECB 2020 provisions via an ABC edition — confirm exact in-force date vs. permit application date
None widely mandated beyond ABC; check City of Calgary bylaws
Edmonton
Alberta
~5,100–5,200
Zone 7A
Alberta Building Code — confirm NECB 2020 adoption date
Same provincial code as Calgary; zone boundary close to 7A/6 — confirm with Appendix C data for exact site
City of Edmonton may reference its own energy/resilience policies for larger commercial permits
Kelowna
British Columbia
~3,000–3,250 (borderline 4/5)
Zone 5
BC Building Code (references NECB 2020)
BC layers the BC Energy Step Code on top of NECB minimums — applicable Step is set locally, not by NECB
BC Energy Step Code — mandatory tier depends on building type and Kelowna's current bylaw; often exceeds NECB prescriptive minimums
⚠ Items above marked with adoption/overlay notes vary by permit date or local bylaw — confirm against the current in-force code text before design freeze.


Opaque Assembly Minimums (NECB 2020, Prescriptive Path)

Values are EFFECTIVE RSI/R (after thermal bridging), Imperial R-value in parentheses. Confirm exact values against NECB 2020 Table 3.2.2.2 / 3.2.2.3.
Assembly
Toronto — Zone 6
Calgary — Zone 7A
Edmonton — Zone 7A
Kelowna — Zone 5
Roof (effective)
RSI 8.6 (~R-49)
RSI 5.0–5.46 (~R-28.5–31)
RSI 5.0–5.46 (~R-28.5–31)
RSI 4.6 (~R-26)
Above-grade wall — wood/steel frame (effective)
RSI 3.7 (~R-21)
RSI 4.05 (~R-23)
RSI 4.05 (~R-23)
RSI 3.34 (~R-19)
Above-grade wall — mass (concrete/CMU/tilt-up) (effective)
RSI 2.4 (~R-14)
RSI 2.6 (~R-15)
RSI 2.6 (~R-15)
RSI 2.1 (~R-12)
Below-grade wall / foundation (effective)
RSI 2.3 (~R-13)
RSI 2.5 (~R-14)
RSI 2.5 (~R-14)
RSI 1.9 (~R-11)
Slab-on-grade, heated (effective, perimeter)
RSI 1.3 (~R-7.5)
RSI 1.4 (~R-8)
RSI 1.4 (~R-8)
RSI 1.1 (~R-6.5)
Floor over unheated/exterior space (effective)
RSI 4.9 (~R-28)
RSI 4.9–5.02 (~R-28–28.5)
RSI 4.9–5.02 (~R-28–28.5)
RSI 4.9 (~R-28)
Notes:
  • Steel-stud walls almost always need continuous exterior insulation (mineral wool/XPS/EPS) to reach the effective-R target — stud-bay batt alone won't comply.
  • Mass wall targets are lower than frame wall targets — NECB credits thermal mass/storage benefit.
  • Below-grade requirement applies to foundation walls enclosing heated space; unheated below-grade space has separate (lower) requirements.
  • Heated slabs (in-floor radiant, heated loading docks) trigger the slab-edge minimum; unheated slabs are exempt.
  • Prescriptive path only. Trade-off (NECB 3.3) or whole-building performance path (NECB 4 / Div. B Part 8) can permit lower R in one assembly if compensated elsewhere — common for high-glazing commercial buildings.


Glazing / Fenestration Performance (NECB 2020, Prescriptive Path)

USI = overall U-value in W/(m²·K), lower is better. FDWR = Fenestration and Door to Wall Ratio.
Parameter
Toronto — Zone 6
Calgary — Zone 7A
Edmonton — Zone 7A
Kelowna — Zone 5
Max USI — vertical glazing (fixed)
~1.90–2.00 (U-0.34–0.35)
~1.60–1.90 (U-0.28–0.33)
~1.60–1.90 (U-0.28–0.33)
~2.00–2.20 (U-0.35–0.39)
Max USI — operable/entrance doors w/ glazing
Slight relaxation vs. fixed glazing
Slight relaxation vs. fixed glazing
Slight relaxation vs. fixed glazing
Slight relaxation vs. fixed glazing
Skylights — max USI
Higher (less stringent) than vertical glazing
Higher (less stringent) than vertical glazing
Higher (less stringent) than vertical glazing
Higher (less stringent) than vertical glazing
FDWR cap — simple prescriptive path
40% typical cap
40% typical cap
40% typical cap
40% typical cap
SHGC
Not fixed by prescriptive path
Not fixed by prescriptive path
Not fixed by prescriptive path
Not fixed by prescriptive path
Notes:
  • USI tightens as HDD rises — triple glazing or thermally broken curtain wall typically needed in Zone 7A to hit the lower end.
  • Above the ~40% FDWR cap, NECB pushes the project toward trade-off or performance-path compliance — common for curtain-wall-heavy commercial designs.
  • SHGC isn't fixed on the simple prescriptive path but becomes a real driver once you're in energy modelling or under a provincial overlay (e.g., BC Energy Step Code).
  • Kelowna specifically: confirm the applicable BC Energy Step Code tier with the City of Kelowna — Step 3+ commercial targets can be materially stricter on glazing/airtightness than the NECB prescriptive minimum shown here.


Sources & Assumptions

  • Primary reference: NECB 2020, Division B — Table 3.2.2.2 (opaque assemblies) and Table 3.2.2.3 (fenestration/doors), by climate zone.
  • Structural/life-safety reference: NBC 2020, where a province hasn't issued its own building code text.
  • Climate zone data: NECB 2020 Appendix C (Climatic Design Data). HDD18 values above are approximate — confirm the exact figure for each project site before finalizing the design basis.
  • Provincial adoption — critical: Every province amends/adopts NECB/NBC on its own schedule. ON (SB-10), AB (Alberta Building Code), and BC (BC Building Code) may reference an earlier or amended edition depending on permit date. Confirm the in-force edition with each province's building code office.
  • Local overlays to check: Toronto Green Standard; BC Energy Step Code tier (Kelowna); any municipal energy/GHG bylaws in Calgary/Edmonton.
  • Compliance path assumed: Simple/prescriptive path only. Trade-off and whole-building performance paths can yield more favourable outcomes, especially for FDWR above ~40%.
  • Effective vs. nominal R-value: All values above are effective R (post thermal-bridging), not nominal insulation R-value.
  • Recommended next step: Confirm every value against the primary source, cell by cell, for each project's exact address before design freeze.


Programa for LP Proto

There is a LP Prototype project in Programa that has been pre-populated with all of these specs. It will also allow you to copy products, or even whole sections to new Programa projects.
The dashboard for the Programa specs is here: https://app.programa.design/share/davignon-martin-a-id/7wrae4 


AF## /// Architectural Finishes

Code
Description
Spec
AF01a
CIP Concrete
CIP ConcreteFinish: Exposed CIP Concrete
AF01b
Precast Concrete Smooth
PrecastFinish: Exposed Precast Concrete
AF01
Precast Concrete Formliner, Reclaimed Wood
Reckli Formliner on PrecastModel: 2/240 BaliFinish: Exposed Precast Concrete
AF02
Aluminum Fluted Wall Panels in Black
NortwoodModel: DSoal Aluminum Fluted PanelsMullion Size: 2.5"W x 10.5" BacksectionPanel: Vision & SpandrelRefer to Detailed CW Specifications
AF03
Sheet Metal Flashing in Black
Jay's Metal or EquivalentModel: Sheet Metal FlashingFinish: BlackProfile: Refer to Details
AF04
Weathering Steel Panels
Corten or EquivalentFinish: Weathering SteelRefer to Details for Z-Girt Subsystem
AF05
Fibre-Cement Panels in Charcoal Gray cw Aluminum Trim
HardiePanel & EasyTrim (AF05a)Finish: Midnight SootSize: 4' x 12' Max
AF05a
Aluminum Panel Trim System in Charcoal Gray
EasyTrimProfiles: VariousFinish: Paint to Match Panel
AF06
Aluminum Soffit Panel in Wood Texture
LUXModel: Double 7Finish: WalnutPattern: 4 Solid, 1 Vented
AF07
Two-Ply Mod-Bit Roofing Membrane in Charcoal Grey
Soprema or EquivalentSystem: SBS Mod-BitFinish: Charcoal Gray Cap Sheet

Elevation Notes

Written by Gregoire Dechaine 26/07/27
This applies to all Launchpad Locations following the LP Prototype
#
Note
401
Exposed CIP Concrete (AF01a)
402
Exposed Precast Concrete (AF01b)
403
Exposed Precast Concrete cw. Reclaimed Wood Texture (AF01)
404
Aluminum Fluted Wall Panels in Black (AF02)
405
Weathered Steel Panel System (AF04)
406
Fibre Cement Panel cw Aluminum Trim in Black (AF05/AF05a)
407
Vented Soffit Panels in Wood Texture (AF06)
408
Two-Ply Mod-Bit Roofing Membrane in Charcoal Grey (AF07)
409
Aluminum Guardrail in Black
410
Aluminum Gate in Black
411
Metal Downspout in Black
412
Scupper - Refer to Roof Plan
413
Metal Cap Flashing in Black (AF03)
414
Metal Gutter and Fascia in Black (AF03)
415
Metal Flashing in Black (AF03)
416
Feature Entry Door in Wood
417
Exterior Door in Black
418
Curtain Wall - Black Frame cw. Vision Glass
419
Automatic Sliding Door - Black Frame cw. Vision Glass
420
Concrete Stairs
421
Concrete Retaining Wall
422
Metal and Wood Screening Wall
423
Metal and Wood Waste Enclosure
424
Entrance Feature Pergola - Refer to Details
425
Launchpad Workmark Signage - Refer to Signage Details
426
Launchpad 20' Wall Logo - Refer to Signage Details
427
Exterior Lighting Fixture - Refer to Lighting Schedule
428
Bike Hoop Rack in Black
429
Landscaping - Refer to Landscape Drawings
430
Rooftop Screening - Refer to Details

CW## /// Curtain Walls

Code
Description
Spec
CW6
Curtain Wall System 2.5"W x 6" Back
KawneerModel: 1600 Wall System 1Mullion Colour: Matte BlackMullion Size: 2.5"W x 6" BacksectionPanel: Vision & SpandrelRefer to Detailed CW Specifications
CW75
Curtain Wall System 2.5"W x 7.5" Back
KawneerModel: 1600 Wall System 1Mullion Colour: Matte BlackMullion Size: 2.5"W x 7.5" BacksectionPanel: Vision & SpandrelRefer to Detailed CW Specifications
CW105
Curtain Wall System 2.5"W x 10.5" Back
KawneerModel: 1600 Wall System 1Mullion Colour: Matte BlackMullion Size: 2.5"W x 10.5" BacksectionPanel: Vision & SpandrelRefer to Detailed CW Specifications

Detailed CW Specifications

Building Fenestration Performance Requirements
  • For codes based on NBC 2020
  • Calculations based on AAMA/WDMA/CSA 101/I.S. 2/A440-17 (NAFS-17) & CSA A440S1-19 CANADIAN SUPPLEMENT TO NAFS-17
  • FEB 2017 | CSA A440S1-19
  • Building Information
  • Location = Calgary, AB
  • Terrain Type = Open Terrain - where open terrain is level terrain with only scattered buildings, trees or other obstructions, open water or shorelines.
  • Building Type = Part 3, Commercial (CW)
  • Product Information
  • Product Height Off Grade = > 10m
  • Performance Requirements, Class CW
  • Minimum Performance Grade (PG) = CW30
  • Minimum Positive Design Pressure = 1440 PA
  • Minimum Negative Design Pressure = -1440 PA
  • Minimum Water Penetration Resistance Test Pressure = 260 PA
  • Minimum Canadian Air Infiltration/Exfiltration = A2


Curtain Wall Panel Schedule

Code
Curtain Wall Panels
Spec
V1
Vision Panel
Clear Vision GlassType: Tempered Float Glass, Argon FilledColour: ClearCoating: Low-E #2
V2
Vision Panel w Bird-Friendly Glazing
Clear Vision GlassType: Tempered Float Glass, Argon FilledColour: ClearCoating: Low-E #2Application: Ceramic Frit Patter for Bird DeterrenceNote: Requires Bird-Friendly Glazing Pattern - Refer to Details
S
Spandrel Panel
ACM on SpandrelType: Insulated Metal Backpan cw ACM CladdingColour: BlackRefer to Details for Connection


Curtain Wall Mullion Schedule

Code
Curtain Wall Mullions
Spec
A
Standard Flat Cap
KawneerModel: Standard Flat CapColour: Matte Black
B
Structural Sealant & Pressure Plate
KawneerModel: Standard SealantColour: Black Sealant


D## /// Doors

Code
Description
Spec
D01
Feature Entry Door
Custom Solid Wood Door in Metal FramePull: Custom Pull / Either Side DH14Refer to Door Schedule for Sizing
D02
Vestibule Entry Door
KawneerModel: 350 Standard EntranceFinish: BlackConfig: Double DoorsSize: Panel x2 3'-5" = 6'-10"(w) x 8'-10"(h)Pull: Custom Pull / Either Side DH14Mounted in Curtain WallRefer to Door Schedule for Sizing
D03
Overhead Coiling Door for Ball Room
RaynorModel: DuraCoil IFFinish: Stainless SteelSize: 6'-0"(W) x 8'-0"(H)Operation: Motorized DH02Steel Jamb Protection RequiredRefer to Door Schedule for Sizing
D04
Breakaway Automatic Sliding Door
Stanley Access SolutionsModel: Dura-Glide 3000Finish: BlackSize: Panel x2 3'-6" = 7'-0"(w) x 7'-6"(h)Sidelites x2 3'-10" = 7'-8"(w) x 7'-6"(h)Operation: Automatic Bi-Part cw BreakawayRefer to Door Schedule for Sizing
D05
Insulated Metal Door & Expandable Frame
DaybarModel: MaxDoor Insulated Panel cw EF FramesFinish: Paint-Grade, Paint PT\|03Refer to Door Schedule for Sizing
D05
Rated Metal Door & Expandable Frame
DaybarModel: ULC Rated MaxDoor MX1 Panel cw EF FramesFinish: Paint-Grade, Paint PT\|03Refer to Door Schedule for Sizing
D07
Solid Wood Door & Metal Frame
Solid Core Wood Panel cw Metal FrameModel: Supplier to Provide Shop DrawingsFinish: Paint-Grade, Paint PT\|03Refer to Door Schedule for Sizing

DH## /// Door Hardware

Code
Description
Spec
DH01
Door Kick Plate
Assa AbbloyModel: Aluminum Sheet Kick PlateColour: Black
DH02
Overhead Door Motor
Manaras-OperaModel: Opera-MH OMH
DH03
Door Closer
Hager CompaniesModel: 5100 SeriesFinish: Black
DH04
Heavy-Duty Door Closer
Hager CompaniesModel: 5200 SeriesFinish: Black
DH05
Privacy Lockset w Indicator
Hager CompaniesModel: 3796Finish: Satin Chrome US26DOptions: August Lever
DH06
Commercial Grade Hinges
Hager CompaniesModel: AB700Finish: Satin Chrome US26DSize: 4" x 4"
DH07
Floor Mounted Door Stop
Gallery Assa AbloyModel: GSH 210Finish: Stainless Steel
DH08
Mortise Lockset - Storeroom
Sargent Assa AbloyModel: 7900 SeriesFinish: Black BSPFunction: 04 Storeroom F07Lever: MD LeverRose: E3 Rose
DH09
Mortise Lockset - Passage
Sargent Assa AbloyModel: 7900 SeriesFinish: Black BSPFunction: 15 Passage F01Lever: MD LeverRose: E3 Rose
DH10
Mortise Lockset - Privacy
Sargent Assa AbloyModel: 7900 SeriesFinish: Black BSPFunction: 66 Privacy F19Lever: MD LeverRose: E3 Rose
DH11
Door Push Plate
Rockwood Assa AbloyModel: 71GFinish: Black BSPSize: 4" x 20"
DH12
Door Pull Handle
Rockwood Assa AbloyModel: 126-RKWFinish: Black BSPSize: 4" x 20"
DH13
Commercial Grade Double-Acting Hinges
Hager CompaniesModel: 1303-4Finish: Satin Chrome US26DSize: 3 1/2" x 4"
DH14
Custom Entry Door Pull
Canadian Builders HardwareModel: CBH 6041-3Finish: Flat Black C19Diameter: 1-1/2"Length: 36"
DH15
Commercial Air Curtain
OuelletModel: ORA-HX HX2000ENTECO480VVolts: 480 (3) + 208 or 240Amp: 31.7Weight: 135lbFinish: Dark Grey
DH16
Exit Device, Push-Bar
Von-DuprinModel: 9875-F/9975-F Mortise Lock Fire Exit DeviceFinish: Satin ChromeTrim: 990 Trim
DH17
ADO (Automatic Door Operator)
StanleyModel: M-ForceFinish: BlackPush Button Operators, Refer to Construction Plan

DHG## /// Door Hardware Groups

Code
Description
Spec
DHG01
Interior Doors - Private Washroom
Lever / Lockset: Privacy Lockset w Indicator DH05Hinges: x3 / Panel - Commercial Grade Hinges DH06Door Stop: Floor Mounted Door Stop DH07
DHG02
Interior Doors - Passage cw Closer
Lever / Lockset: Mortise Lockset - Passage DH09Hinges: x3 / Panel - Commercial Grade Hinges DH06Closer: Heavy-Duty Door Closer DH04Kick-Plate: x2 / Panel - Door Kick Plate DH01Door Stop: Floor Mounted Door Stop DH07
DHG03
Interior Doors - Storeroom
Lever / Lockset: Mortise Lockset - Storeroom DH08Hinges: x3 / Panel - Commercial Grade Hinges DH06Kick-Plate: x2 / Panel - Door Kick Plate DH01Door Stop: Floor Mounted Door Stop DH07
DHG04
Interior Doors - Public Washroom Entry cw Closer
Push: Door Push Plate DH11Pull: Door Pull Handle DH12Hinges: x3 / Panel - Commercial Grade Hinges DH06Closer: Heavy-Duty Door Closer DH04Kick-Plate: x2 / Panel - Door Kick Plate DH01Door Stop: Floor Mounted Door Stop DH07
DHG05
Interior Doors - Double Acting Kitchen Entry
Hinges: x3 / Panel - Commercial Grade Double-Acting Hinges DH13Push: x2 / Panel - Door Push Plate DH11Kick-Plate: x2 / Panel - Door Kick Plate DH01Door Stop: x2 / Either Side - Floor Mounted Door Stop DH07
DHG06
Interior Doors - Vestibule Entry
Manufacturer Provided Hardware D02Pull: Custom Pull / Either Side DH14Closer: Yes w ADO DH17Threshold: YesWeatherstripping: YesDoor Stop: Floor Mounted Door Stop DH07
DHG07
Interior Doors - Office
Lever / Lockset: Mortise Lockset - Privacy DH10Hinges: x3 / Panel - Commercial Grade Hinges DH06Kick-Plate: x2 / Panel - Door Kick Plate DH01Door Stop: Floor Mounted Door Stop DH07
DHG08
Exterior Doors - Feature Entry
Manufacturer Provided Hardware D01Pull: Custom Pull / Either Side DH14Closer: Yes w ADO DH17Threshold: YesWeatherstripping: YesDoor Stop: Floor Mounted Door Stop DH07
DHG09
Exterior Doors - Egress
Hinges: x3 / Panel - Commercial Grade Double-Acting Hinges DH13Exit Device: Exit Device, Push-Bar DH16Closer: Heavy-Duty Door Closer DH04Threshold: YesWeatherstripping: YesDoor Stop: Floor Mounted Door Stop DH07
DHG10
Exterior Doors - Storeroom
Lever / Lockset: Mortise Lockset - Storeroom DH08Hinges: x3 / Panel - Commercial Grade Hinges DH06Kick-Plate: x2 / Panel - Door Kick Plate DH01Closer: Heavy-Duty Door Closer DH04Threshold: YesWeatherstripping: YesDoor Stop: Floor Mounted Door Stop DH07
DHG11
Exterior Doors - Private Washroom cw Closer
Lever / Lockset: Privacy Lockset w Indicator DH05Hinges: x3 / Panel - Commercial Grade Hinges DH06Closer: Door Closer DH03Threshold: YesWeatherstripping: YesDoor Stop: Floor Mounted Door Stop DH07
DHG12
Exterior Door - Ballroom Overhead
Manufacturer Provided Hardware D03Motor: Overhead Door Motor DH02
DHG13
Exterior Door - Automatic Sliding Door
Manufacturer Provided Hardware D04Operation: MotionThreshold: YesWeatherstripping: YesLockout/Override: YesAir Curtain Required DH15

FR## /// Furniture

Code
Description
Spec
FR01
Indoor High-Top Table Seat
Owner Specified. As per Client's Layout and Design Requirements.
FR02
Indoor Dining Table Seat
Owner Specified. As per Client's Layout and Design Requirements.
FR03
Indoor Booth Seat
Owner Specified. As per Client's Layout and Design Requirements.
FR04
Indoor Bar Stool
Owner Specified. As per Client's Layout and Design Requirements.
FR05
Indoor Sofa
Owner Specified. As per Client's Layout and Design Requirements.
FR06
Indoor Side Table
Owner Specified. As per Client's Layout and Design Requirements.
FR07
Indoor 4 Seat High-Top Table cw. Pedestal
Owner Specified. As per Client's Layout and Design Requirements.
FR08
Indoor 4 Seat Table cw. Pedestal
Owner Specified. As per Client's Layout and Design Requirements.
FR09
Indoor Console Table cw. Chargers
Owner Specified. As per Client's Layout and Design Requirements.
FR10
Indoor 6 Seat Table
Owner Specified. As per Client's Layout and Design Requirements.
FR11
Indoor Coffee Table
Owner Specified. As per Client's Layout and Design Requirements.
FR12
Indoor Booth Table cw. Pedestal
Owner Specified. As per Client's Layout and Design Requirements.
FR13
Outdoor Coffee Table
Owner Specified. As per Client's Layout and Design Requirements.
FR14
Outdoor Tabletop Seat
Owner Specified. As per Client's Layout and Design Requirements.
FR15
Outdoor Lounge Seat
Owner Specified. As per Client's Layout and Design Requirements.
FR16
Outdoor Sofa
Owner Specified. As per Client's Layout and Design Requirements.
FR17
Outdoor Table
Owner Specified. As per Client's Layout and Design Requirements.

LF## /// Lighting Fixtures

Code
Description
Spec
LF01
Exterior LED Surface Mount Downlight for Pergola
EurofaseFixture: KiloModel: 28281-054Colour: BlackMount: Surface Mount
LF02
Exterior LED Wall Mount Downlight
EurofaseFixture: ArenaModel: 50728-015Colour: BlackMount: Wall Mount
LF03
Exterior LED Ceiling Pendant for Hitting Bays
LampoliteFixture: Dome 36" BlackModel: Dome 36" BlackMount: Ceiling Pendant
LF04
Exterior LED RGB Surface Mount Spot
Gemstone / iPixel LEDFixture: LED LampMount: Surface Mount
LF05
Exterior LED RGB Strip Lighting
Gemstone / iPixel LEDFixture: LED StripMount: Surface Mount
LF06
Site Lighting - LED Light Standard, 25' Pole Single Light
Landscape FormsFixture: CandelaModel: CLP 25-A AL SBC R MS1 TW1 UDG*Site Lighting Analysis Required
LF07
Site Lighting - LED Light Standard, 25' Pole Dual Light
Landscape FormsFixture: CandelaModel: CLP 25-B AL SBC R MS1 TW1 UDG*Site Lighting Analysis Required
LF08
Site Lighting - LED Bollard Light
Landscape FormsFixture: Outline BollardModel: DW102 27K T5 BLK
LF09
Site Lighting - LED Pathway Lighting
Flexa LightingFixture: Mal 10Model: MA1309NColour: BlackMount: Recessed in Concrete
LF10
2'x2' LED Panel Light
LitelineFixture: Forum LED Panel LightModel: LEDP-22WH-35-40-120/277Mount: Frame in Ceiling Grid
LF11
Atrium 16' Linear LED Light
MarkFixture: Slot 1 PendantModel: S1LI-LOP-16FT 90CRI 30K 600LFM MIN1 MVOLT ZTMount: Ceiling Pendant
LF12
4' Linear LED Light
MarkFixture: Slot 4 PendantModel: SL4D-LLP-4FT 90CRI З0K 600LFM MIN1 MVOLT ZTMount: Ceiling Pendant
LF13
LED Perimeter Linear Lighting
MarkFixture: Slot 4 PerimeterModel: S4CD-LOP-4FT 90CRI З0K 600LFM MIN1 MVOLT ZTMount: Ceiling in Alcove*Length specified on RCP
LF14
LED Recessed Light
EurofaseFixture: Amigo 1 Light RoundModel: 35143-30-01Colour: BlackMount: Ceiling Recessed
LF15
4' Recessed Linear LED Light for Entry
MarkFixture: Slot 4 RecessedModel: S4RD-LOP-4FT 90CRI З0K 600LFM MIN1 MVOLT ZTMount: Ceiling Recessed
LF16
LED Ceiling Pendant Arrangement
Visual Comfort & CoFixture: Soco PendantModel: M 08 B WColour: Black Chord, White HolderMount: Ceiling Pendant
LF17
LED Ceiling Pendant
LampoliteFixture: Double Drum 24Model: AB-DRUM-SH+SH-SC-24-INCColour: Kona BlackMount: Ceiling Pendant
LF18
LED Recessed Mini Sconce
U TechnologyFixture: PXL RoundModel: UT-PL-24VColour: BlackMount: Recessed in Wall Base
LF19
LED Pendant for Lounge
Matteo LightingFixture: Large PendantModel: C33708MBColour: BlackMount: Ceiling Pendant
LF20
LED Recessed Light for Washrooms
FluxwerxFixture: Portal Recessed 9"Model: TC1-R 09 D K2 B B M1 9 30Colour: BlackMount: Ceiling Recessed
LF21
LED Pendant for Lounge
Arkansas LightingFixture: P170AModel: P170A-S-150150150150180-180180180180125-LS14-DR-P060Mount: Ceiling Pendant

MW## /// Millwork

Code
Description
Spec
MW01
Entry Kiosk
Owner Specified. As per Client's Layout and Design Requirements.
MW02
Display Shelves
Owner Specified. As per Client's Layout and Design Requirements.
MW03
Entrance Counter / Signage Wall
Owner Specified. As per Client's Layout and Design Requirements.
MW04
Office Desk
Owner Specified. As per Client's Layout and Design Requirements.
MW05
Booth Seating
Owner Specified. As per Client's Layout and Design Requirements.
MW06
Lounge Bar
Owner Specified. As per Client's Layout and Design Requirements.
MW07
Lounge Backbar
Owner Specified. As per Client's Layout and Design Requirements.
MW08
Women's Washroom Sinks
Owner Specified. As per Client's Layout and Design Requirements.
MW09
Men's Washroom Sinks
Owner Specified. As per Client's Layout and Design Requirements.
MW10
Kitchen Eating Bar
Owner Specified. As per Client's Layout and Design Requirements.
MW11
Server Station
Owner Specified. As per Client's Layout and Design Requirements.
MW12
Staff Washroom Sink
Owner Specified. As per Client's Layout and Design Requirements.
MW13
Swing Suite Column Cover
Owner Specified. As per Client's Layout and Design Requirements.
MW14
Swing Suite Half-Column Cover
Owner Specified. As per Client's Layout and Design Requirements.
MW15
Mezzanine Bar
Owner Specified. As per Client's Layout and Design Requirements.
MW16
Mezzanine Backbar
Owner Specified. As per Client's Layout and Design Requirements.
MW17
Ceiling Grid Section
Owner Specified. As per Client's Layout and Design Requirements.
MW18
Atrium Screen Wall
Owner Specified. As per Client's Layout and Design Requirements.

OH## /// Other Hardware

Code
Description
Spec
OH01
Surface Mounted Coat Hook
BobrickModel: B-682Finish: Stainless Steel
OH02
18" Surface Mounted Grab Bar
BobrickModel: B-5806x18Finish: Stainless Steel
OH03
24" Surface Mounted Grab Bar
BobrickModel: B-5806x24Finish: Stainless Steel
OH04
L-Shape Surface Mounted Grab Bar
BobrickModel: B6898.99Finish: Stainless Steel
OH05
Wall Mounted Hand Dryer
SloanModel: XLERATOR EHD-501Finish: Graphite
OH06
Double Tier Locker
HadrianModel: Emperor LockersType: Powder Coated Double Tier LockersFinish Anti-Graffiti FinishColor: 576 Ruby RedDimensions: 12" × 72"Accessories: Dress Ends; Number Plates; HooksLocking Device: Friction CatchLocking Option: "A" Padlock
OH07
Surface Mounted Sanitary Napkin Disposal
BobrickModel: B270Finish: Stainless Steel
OH08
Surface Mounted Tissue Dispenser
BobrickModel: B2888Finish: Stainless Steel

SE## /// Specialties

Code
Description
Spec
SE01
Driving Range Tee Pad
Artificial Truf Driving Range Pad. As per Client's Layout and Design Requirements.
SE02
Ball Dispenser & Screen
Range Servant Ball Dispenser. As per Client's Layout and Design Requirements.
SE03
LaunchPad Golf Bag Holder
Golf Bag Holder. As per Client's Layout and Design Requirements.
SE04
Bike Hoop Rack in Black
DeroModel: Hoop Rack Heavy DutyFinish: BlackMount: In-Ground
SE05
Matte Black Bar Foot Rail System
KegworksModel: BLK-BARRAIL-KITColour: Matte BlackOptions: 2" Outer Diameter, 90 Deg. Post Bracket & Flush Flat End CapsLength: 8'Note: Various Parts, Outdoor Application Available
SE06
Matte Black Drink Rail System
KegworksModel: DR-MBHEM-XXColour: Matte BlackOptions: Add Perforated Drip Trays as RequiredLength: 8'Note: Various Parts, Outdoor Application Available

WB## /// Wall Bases

Code
Description
Spec
WB01
Vinyl Wall Base
Artificial Truf Driving Range Pad. As per Client's Layout and Design Requirements.
WB02
Tile Wall Base to Match TF|02
Use Tile Finish TF\|02Note: Wall base seams are to align with floor tile seams.
WB03
Tile Wall Base to Match TF|04
Use Tile Finish TF\|04Note: Wall base seams are to align with floor tile seams.

##|## /// Interior Finishes

Code
Finish
Spec
CO|##
Concrete
Spec
CO|01
Exposed CIP Concrete
Exposed Architectural FinishNote: Seal in Matte as Required
CO|02
Exposed Formliner on Precast Concrete
Exposed Architectural Finish
CO|03
Exposed Precast Concrete
Exposed Architectural Finish
CT|##
Ceiling Finishes
Spec
CT|01
Ceiling Tile for Utility & Kitchen
ArmstrongStyle: Clean Room VL - 870Colour: PT|01 (Dark Gray) Application: Spray Applied Paint on CeilingSize: 24" x 24"
FF|##
Floor Finish
Spec
FF|01
FF|02
Carpet Tile for Office
Shaw ContractStyle: PlainsColour: Remote 71580Install Pattern: AshlarSize: 46 cm x 91 cm | 18 in x 36 in
FF|03
Epoxy for Kitchen & Utility Rooms
Dymond CoatingsStyle: 3-Part EpoxyColour: Dark Grey
GL|##
Glass
Spec
LQ|##
Lacquer
Spec
MI|##
Mirror
Spec
ML|##
Melamine
Spec
MT|##
Metal
Spec
MT|01
Metal Finish for Kitchen Passthrough Screen
MT|02
Metal Finish for Kitchen Passthrough Bar
MT|03
Corten Wall Paneling
MT|04
PL|##
Plastic Laminate
Spec
PT|##
Paint
Spec
PT|01
Interior Ceiling Paint
Benjamin MooreColour: AF-655 SilhouetteFinish: Flat/MatteApplication: Spray Applied
PT|02
Interior Wall Paint
Benjamin MooreColour: OC-68 Distant GrayFinish: EggshellApplication: Roller Applied
PT|03
Exterior/Interior Door & Trim Paint
Benjamin MooreColour: 2120-20 Jet BlackFinish: SatinApplication: Spray Applied
PT|04
Interior Wall Paint
Benjamin MooreColour: AF-655 SilhouetteFinish: EggshellApplication: Roller Applied
PT|05
Interior Guardrail Paint
Benjamin MooreColour: 2021-30 Sunshine YellowFinish: Semi-GlossApplication: Spray Applied
SF|##
Specialty Finishes
Spec
SF|01
FRP Laminate Panels Food Safe
TCHStyle: 1/2in Textured Fiberglass (FRP) Laminate - WhiteModel: 510-7660911|4x3Panel Size: 96" x 48"
ST|##
Stone
Spec
ST|01
Stone for Front Desk
Stone Tile WestStyle: OssidoFinish: PolishedType: Solid Surface LaminaColour: NeroSlab Size: 1000mm x 3000mm
ST|02
Stone for Bar Countertops
SilestoneStyle: Granite 3cm ThickFinish: Polished w Double Thick Chiseled EdgeType: Solid SurfaceColour: Night Tebas 18Slab Size: 327cm x 159 cm
ST|03
Stone for Washroom Countertops
VicostoneStyle: Vicostone 3cm ThickFinish: PolishedType: Solid SurfaceColour: Sparkling Gray BC217Slab Size: 144cm x 305cm
TF|##
Tile Finish
Spec
TF|01
Floor Tile for Entry
Stone Tile WestStyle: Woodland Series PWOL-CHER-BRD-02001200-NATU-010-00Color Code: Cherry WoodSeries Finish: NaturalNominal Size: 8" x 48"Grout Line Width: 1/8"Grout Color Code: #386 Oyster Grey
TF|02
Floor Tile in Weave Pattern
Requires Several Tile Specs in Pattern:A - 24" x 24" in Dark GrayOlympia TileStyle: Regal Series NY.RG.DGR.2424.FLColor Code: Dark GreySeries Finish: FlamedNominal Size: 24" x 24"B - 12" x 24" in GrayOlympia TileStyle: Regal Series NY.RG.GRY.1224.FLColor Code: GreySeries Finish: FlamedNominal Size: 12" x 24"C - 8" x 48" Faux Wood Finish TileStone Tile WestStyle: Woodland Series PWOL-CHER-BRD-02001200-NATU-010-00Color Code: Cherry WoodSeries Finish: NaturalNominal Size: 8" x 48"D - 12" x 24" in BlackOlympia TileStyle: Regal Series NY.RG.JBK.1224.FLColor Code: Jet BlackSeries Finish: FlamedNominal Size: 12" x 24"/// Grout for All Tile in Pattern:Grout Line Width: 1/8"Grout Color Code: #386 Oyster Grey
TF|03
Floor Tile for Washroom
Olympia TileStyle: Regal Series NY.RG.DGR.2424.FLColor Code: Dark GreySeries Finish: FlamedNominal Size: 24" x 24"Grout Line Width: 1/8"Grout Color Code: #386 Oyster Grey
TF|04
Floor Tile for Bar Areas
DaltileStyle: Quarry TileColor Code: Arid Gray 0Q42Series Finish: NaturalNominal Size: 6" x 6"Grout Line Width: 1/8"Grout Color Code: #542 Graystone
TF|05
Wall Tile for Washroom
Stone Tile WestStyle: Progretto Ceramiche CPRC-PER0715MColor Code: PerlaSeries Finish: MatteNominal Size: 3" x 6"Grout Line Width: 1/8"Grout Color Code: #381 Bright White
TF|06
Wall Tile for Washroom
Julian TileStyle: Elegance Pro EPROAN2448NColor Code: Anthracite NaturalSeries Finish: MatteNominal Size: 24" x 48"Grout Line Width: 1/8"Grout Color Code: #60 Charcoal
TF|07
Wall Tile for Kitchen Passthrough
Stone Tile WestStyle: Glass GLAS-WT-TIBR-02000200-007-GLOS-URColor Code: Glass Titanium BrickSeries Finish: GlassNominal Size: 8" x 8"Grout Line Width: 1/8"Grout Color Code: #540 Truffle
TF|08
Wall Tile for Kitchen Back-of-House
Tierra SolStyle: Contract White Wall WOYPW36GColor Code: White GlossSeries Finish: GlossNominal Size: 3" x 6"Grout Line Width: 1/8"Grout Color Code: #381 Bright White
TFG|60
Cement Grout in Charcoal
CUSTOMStyle: Polyblend HPColour: #60 Charcoal
TFG|381
Cement Grout in White
CUSTOMStyle: Polyblend HPColour: #381 Bright White
TFG|386
Cement Grout in Beige
CUSTOMStyle: Polyblend HPColour: #386 Oyster Gray
TFG|540
Cement Grout in Dark Taupe
CUSTOMStyle: Polyblend HPColour: #540 Truffle
TFG|542
Cement Grout in Taupe
CUSTOMStyle: Polyblend HPColour: #542 Graystone
WC|##
Wallcovering
Spec
WC|01
Vinyl Wallcovering for Washroom
KorosealStyle: Moderne MDN1-14Colour: Ocean LinerRoll Width: 52"-54"
WC|02
Vinyl Wallcovering for Corridor
InnovationsStyle: Sumatra SUM-223Colour: ScallopRoll Width: 36"
WC|03
Vinyl Wallcovering for Washroom Entry Accent
InnovationsStyle: Burnish BUR-006Colour: GunmetalRoll Width: 54"
WC|04
Vinyl Wallcovering for Mezzanine Backbar
Crown Surface SolutionsStyle: Foiled T2-FD-06Colour: IronstoneRoll Width: 50"
WD|##
Wood
Spec
WD|01
Reclaimed Wood Wall Panels
Reclaimed Wood PanelingAvailable Stock
WD|02
Ceiling Detail Wood Finish
UniboardStyle: Eclipse K90Colour: BrownFinish: OmniaSize: 5' x 12'
WD|03
Bathroom Partition Wood Finish
UniboardStyle: Eclipse K90Colour: BrownFinish: DolomiteSize: 5' x 12'
WD|04
Bathroom Door Panel Wood Finish
Ash Wood VeneerColour: Stain to Match WD|03
Weave Pattern:

Proto Rooms

Entry

  • Ceiling Finish - Drywall, Painted in Dark Gray PT|01
  • Lighting - Recessed Fixture in Feature Arrangement x5 Units LF11

Atrium

  • Ceiling Finish - Drywall, Painted in Dark Gray PT|01
  • Lighting - Ceiling Mount Linear in Feature Arrangement x5 Units LF11

Corridors

  • Wall Finish
  • Exposed Precast Formliner
  • Vinyl Wallcovering in Metallic Gray WC|02
  • Floor Finish - 
  • Ceiling Finish - Drywall, Painted in Dark Gray PT|01
  • Lighting
  • Recessed Mini Lights at ~2m O.C. in Corridors LF18
  • Linear Lighting Against Precast LF13
  • 

Kitchen / Back of House / Prep Areas

  • Wall Finish - Drywall, White FRP Laminate Applied OvertopSF|01
  • Ceiling Finish - Ceiling Tiles, Painted in Dark Gray CT|01
  • Floor Finish - Epoxy in Dark Grey FF|03
  • Lighting - Ceiling Mount Linear

Utility Rooms

  • Wall Finish - Drywall, Painted in Dark Gray PT|04
  • Ceiling Finish - Ceiling Tiles, Painted in Dark Gray CT|01
  • Floor Finish - Epoxy in Dark Grey FF|03
  • Lighting - Ceiling Mount Linear LF12

Ball Room

  • Floor Finish - Epoxy in Dark Grey FF|03
  • Lighting - Ceiling Mount Linear LF12

Office

  • Wall Finish - Drywall, Painted in Dark Gray PT|04
  • Ceiling Finish - Ceiling Tiles, Painted in Dark Gray CT|01
  • Floor Finish - Carpet Tiles in Gray FF|02
  • Lighting - Ceiling Grid Mount LF10

Egress Stairwell

  • Wall Finish - Exposed Precast Concrete Panel, Smooth
  • Ceiling Finish - Drywall, Painted in Dark Gray PT|01
  • Lighting - Ceiling Mount Linear LF12

Lounge

  • Ceiling Finish - Drywall, Painted in Dark Gray PT|01
  • Ceiling Detail
  • Place Millwork Ceiling

Mezzanine

  • Millwork
  • Mezzanine Bar MW06
  • Ceiling Finish - Drywall, Painted in Dark Gray PT|01
  • Lighting
  • Ceiling Pendant in Feature Arrangement x30 Units LF16
  • Recessed Lights Above Bar ``

Washrooms

  • Wall Finish
  • Entry Accent Wall, in Corridor Add Vinyl Wallcovering in Black WC|03
  • Lighting
  • Recessed Ceiling Lights LF20


Swing Suites

Swing Suite - Type A

  • Ceiling Finish - Exposed Soffit
  • Lighting
  • x4 LED RGB Spots LF04
  • x2 Ceiling Pendants LF03
  • x1 LED RGB Strip Light LF05
  • Gas Heaters
  • x4 Ceiling Mount Gas Heaters

Exterior

Pergola

  • Framed in 
  • Concrete Round Tubes to Support, cw. Column Saddles
  • Launchpad Wordmark Sign on End
  • Lighting - Surface Mount Fixture on Each Column LF

Signage