- National Building Code - 2023 Alberta Edition Matrix
Existing =New = 1 782 m²Total = 1 782 m²
Existing =New = 3 018m²Total = 3 018m²
Above Grade = 2Below Grade = None
Number of Streets /Access Routes
Building is Group A, Division 2, up to 2 Storeys, Increased Area, Sprinklered
Sprinkler SystemProposed
Water Service /Supply is Adequate?
Mixed Construction; Combustible or Noncombustible Construction Used Singly or in Combination
Mixed Construction; Combustible or Noncombustible Construction Used Singly or in Combination
Mixed Construction; Combustible or Noncombustible Construction Used in Combination
Design of BuildingRefer to Code Plans for Posted Occupant Load as well as Building Code Report for detailed occupancy calculations including exit capacity check.
Occupancy Calc.(O) = Occupancy(L) = Load, persons
Aggregate Occupant Load by Floor:- Level 02 = 220 (L)- Ground Floor = 312 (L)
Required Fire Resistance Rating (FRR/FSR/FWR)
Floors = FSR & 45 Min. FRR if CombustibleMezzanines = 45 Min. FRR if Combustible = 45 Min. FRR or be Noncombustible
Listed Design No(s). or Description (SG-2)
Precast = NBC AE 2023 Appendix D 2.1Wood Loadbearing Partition = ULC W301
Construction of Exterior Walls - Spatial separation will only be considered facing the property lines, as per 1.3.3.5. Refer to 3.2.3. for per Elevation calculations of Spatial Separation.
Limiting Distance = >9mProposed Openings = 10%Permitted Openings = Unlimited
Limiting Distance = >9mProposed Openings = 3%Permitted Openings = Unlimited
Limiting Distance = >9mProposed Openings = 10%Permitted Openings = Unlimited
Limiting Distance = >9mProposed Openings = 3%Permitted Openings = Unlimited
Occupant Load = 532Male = 266, Female = 266Water Closets Req'd Male = 5Water Closets Req'd Female = 10Total Required = 15Ground Floor- Men's Washroom + Barrier Free WC. 2 WC's + 3 Urinals + 2 BF WC's- Women's Washroom + Barrier Free. 5 WC's + 1 BF = 6 WC'sLevel 02- 4 Gender Neutral WC's
Existing: NoneNew: Total:
Above Grade: 2Below Grade: 0
Entire BuildingBasement OnlyIn Lieu of Roof RatingNot Required
3.2.2.20-.903.2.1.53.2.2.17
CombustibleNon-combustibleBoth
CombustibleNon-combustibleBoth
m²/personDesign of Building
(O) = Occupancy(L) = Load, persons
Bsmnt: (O) (L) L01: (O) (L) L02: (O) (L) L03: (O) (L)
Yes / No (Explain)Explanation...
Horizontal Assemblies (Hours)Floors Roof Mezzanine FRR of Supporting Members (Hours)Floors Roof Mezzanine
Construction of Exterior Walls
Comb ConstComb Const cw. Noncomb CladdingNoncomb Const
Area of EBF = m²Limiting Dist = mL / H or H / LFRR = HoursPermitted Max. % OpeningsProposed % of Openings
ListedDesign orDescription
Comb ConstComb Const cw. Noncomb CladdingNoncomb Const
Area of EBF = m²Limiting Dist = mL / H or H / LFRR = HoursPermitted Max. % OpeningsProposed % of Openings
ListedDesign orDescription
Comb ConstComb Const cw. Noncomb CladdingNoncomb Const
Area of EBF = m²Limiting Dist = mL / H or H / LFRR = HoursPermitted Max. % OpeningsProposed % of Openings
ListedDesign orDescription
Comb ConstComb Const cw. Noncomb CladdingNoncomb Const
Area of EBF = m²Limiting Dist = mL / H or H / LFRR = HoursPermitted Max. % OpeningsProposed % of Openings
ListedDesign orDescription
For additional walls, add additional rows as required.
Occupant LoadMale = Female = Water Closet(s) RequirementMale = Female = Water Closet(s) ProvidedMale = B/F IncludedFemale = B/F Included
Specify...
All dimensions on this project to have 'double unit' dims, ie Imperial over Metric dimensions.
- Doors
- Door Schedule
- Door Hardware Groups
- Door Legend
- Door Frame Details (Ask Hugo for Reference)
- Construction Assemblies Schedule
- Walls
- Floors
- Ceilings
- Roofs
- Soffits
- Curtain Wall Elevations
- Room Schedule w Finishes
- Interior Finish Schedule
- scheduling-type-marks > Interior Finishes Schedule
- Tile Weave Pattern Detail (Refer to Heritage)
- Lighting Fixture Schedule
- Furniture Schedule
- Other Hardware Schedule
Drawings for the Enlarged Stairwell Sheets will be combined onto one sheet instead of being separated by series.
All Sections are to be named by their closest gridline; they must also all face the same direction which is to be plan left or plan up depending on the orientation.
- Netting Location(s)
- Indicate Height(s) of Netting on Plan
- Dim Height(s) of Netting in Section
- Berming Location(s)
- Indicate Height(s) of Berming on Plan
- Spot Grade Top/Bottom of Berming in Section
- Range Section
- Building Section
- Dims and Distance to Targets in Yards
- Plans Show Precast Coordination Information Only
- Precast Panel Sizes
- Dims for Precast
- Moment Frames and Locations